Pneumatically (air) Operated Explosion Proof/Dust Ignition Proof Vacuum Cleaner systems

Imperial Sugar   What to do about combustible dusts?
Combustible dusts are a real, tangible threat in today’s industrial world. More and more, they are identified as such by government agencies and worker safety groups worlwide. An article about the devastating consequences of mishandling combustible dusts can be read here.

[View]
 

SSAT-2L "AIR TIGER"
Dry recovery

CEEX II 2 G/D EEx c IIC T6 (85°C)


SSAT-2L-6L
Dry recovery

CE EX II 2 G/D EEx c IIC T6 (85°C)

 

 

SS-10 4W (RE) HEPA
For potent powder recovery (dry)

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • Cleanroom and Pharma compatible
  • Specifically designed for the safe recovery of potent compounds and powders.
  • Primary internal and secondary external HEPA Filtrers as part of a 5-stage filtration system.
  • Safe HEPA filter change.
  • All stainless steel AISI 304 construction (except tilt cart).
  • For dry recovery.
  • Brochure
  • Declaration of conformity.

SS-10 to 55 RE Series
Wet and dry recovery

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • HEPA/ULPA filter.
  • Middle Ring with Activated Carbon (MRAC) available for wet and dry recovery (SS-10 only).
  • Available with an Interceptor unit on a single cart (SS-25 only)
  • All stainless steel AISI 304 construction (except tilt cart).
  • For wet and dry recovery.
  • Based either on a 4 wheel dolly or on a 4 wheel tilting cart to allow for easy emptying of recovered materials.
  • Brochure
  • Interceptor unit: Brochure
  • Declaration of conformity.
 

 

SS-20L DT
Dry recovery

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • HEPA filtration.
  • Equipped with Manual Filter Shaker (MFS).
  • Stainless steel AISI 304 construction (except tilt cart).
  • For dry recovery only.
  • Detachable recovery tank (DT).
  • Brochure
  • Declaration of conformity.

SS-15/40 EX RE HEPA
Automatic filtration systems, dry recovery

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • HEPA/ULPA Filtration available.
  • Available with Automatic Filter Shaker (AFS) or Reverse Pulse System (RPS).
  • All Stainless Steel AISI 304 Construction (AISI 316L Electropolished available).
  • For dry recovery (liquids can be recovered into a separate Immersion recovery tank).
  • Declaration of conformity.
 

 

SS-40L RE HEPA
Dry Recovery

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • HEPA filter included
  • Stainless steel AISI 304 construction.
  • Detachable recovery tank (DT).
  • For dry recovery only.
  • Brochure
  • Declaration of conformity.

SS-35L RE HEPA Series
Dry recovery

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • Stainless steel AISI 304 construction.
  • Available with Manual Filter Shaker (MFS) or Manual Reverse Purge (MRP)
  • Detachable recovery tank (DT).
  • For dry recovery only.
  • Brochure (MFS)
  • Brochure (MRP)
  • Declaration of conformity.
 

 

SS-IT EX (HY-C) HEPA
Wet and Dry recovery

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • HEPA filter included
  • For the recovery and neutralization of conductive and explosive dust into a liquid bath.
  • Hydraulic cart for easy emptying
  • Stainless steel AISI 304 construction.
  • For wet and dry recovery only.
  • Brochure

TVSS-63L EX (MRP)
RE HEPA
Dry recovery

CE 0081 EX II 2 G/D EEx c IIC T6 (85°C)
LCIE 03 ATEX 6310

  • Meets the requirements for:
    Class I – Groups C and D
    Class II – Groups E, F and G.
  • HEPA Filter
  • Stainless steel AISI 304 construction.
  • Manual Reverse Purge (MRP)
  • Single or twin Venturi
  • Detachable recovery tank (DT).
  • For dry recovery only.
  • Brochure
 

Home | Specialty | Cleanroom | Hoppers | Central Vacuum Cleaners | Acid and Corrosive Fuel and Solvent Recovery | Industrial | Explosion Proof | Sanding Kits | Shooting range

Our Quality Standards

Rotina is committed to quality standards and service. We take pride in fulfilling your order promptly from the time you place your order to when it is delivered to you.issa

Parts & Accessories

Rotina’s sales team has years of experience in matching the right blower, fan or pump including parts and accessories for your industry and application.

If you cannot find the product that meets your application needs, please contact us and we will source the right product or recommend an alternative.

Consulting & Customization

If you require engineering advice for your project, we are pleased to offer you our expertise. We have the capability to customize products to meet unique technical, environment or regulatory requirements.

Contact us to find out more.